Sheet E3 · Experimental validation · CALIBRATED

Looped HDPE network, 4 sensors (University of Perugia)

Source : Meniconi, Brunone, Maietta, Zenodo 10.5281/zenodo.5535442 (CC BY 4.0); layout from Maietta's thesis

1. The question

In a real looped network, the wave splits and reflects at every node. Does CBELIER reproduce the pressures measured at several points of a laboratory network with 800 m of pipes?

2. The case

The network includes a DN 110 supply pipe (42 m), two loops in DN 75 and DN 50 (700 m in total) and a DN 25 service branch, closed quickly at its end. Head is measured at the valve (h5u) and at three network nodes (h5, h8, h4).

3. Data and status

DataValueStatus
Measurements at the 4 sensors512 HzPUBLISHED
Layout: lengths, diameters, nodesthesis, table 7.2PUBLISHED
HDPE Kelvin-Voigt parametersthesisPUBLISHED
Initial flow (test 5u_q015)0.15 L/sASSUMED
Closure duration and smoothing19.6 ms; 3.1 msCALIBRATED
Reservoir level; valve area—CALIBRATED

4. Results

102030400.00.20.40.60.81.0time (s)head (m)CBELIER, h5umeasurement, h5uCBELIER, h8measurement, h8
Head at the valve (h5u) and at node h8 over the first second: CBELIER (lines) and measurements (circles, one in six).

5. Differences

IndicatorCBELIERReferenceDifference
Maximum pressure rise at the valve (h5u)20.61 m22.28 m−7.5 %
Maximum pressure drop at the valve (h5u)−13.14 m−13.42 m2.0 %
RMS difference, h5u (2 s)1.98 m——
RMS difference, h5 (2 s)0.13 m——
RMS difference, h8 (2 s)0.17 m——
RMS difference, h4 (2 s)0.09 m——

The extremes at the valve and at the network nodes are reproduced after adjusting only the closure law. Without the viscoelastic model the difference would be about five times larger: this case mainly validates the treatment of the HDPE wall in a looped network.

6. Limitations and assumptions